TDK EPCOS Code B59154U1135B140 Alternative, PTC Thermistor Telecom Overcurrent Overload Protection, Leaded Disk Coated 650V 50Ω 3A

Ceramic PTC thermistor help telecom equipment provide protection against power cross, power induction surges and lighting surge defined in ITU, Telcordia, UL. Compliant with ITU-T K20 K21 K45. 

AMWEI PTC Thermistor for Telecom Overcurrent Protection Leaded Disk Coated Outlook Dimension

Telecom PTC Leaded Disk Coated Appearance Engineering Drawing

Telecom PTC Leaded Disk Coated Appearance Engineering Drawing

  • Silicon resin coated ceramic body, grey color
  • Coated ceramic body outer diameter D : 9.5mm max.
  • Coated ceramic body thickness T: 5.5mm max.
  • Pin wire diameter d: 0.6mm

AMWEI PTC Thermistor for Telecom Overcurrent Protection Leaded Disk Coated  Application

Overcurrent overload protection for telecom applications
Suitable for line card applications e.g. POTS, access networks,
customer premises equipment (CPE) or integrated voice data (IVD)

AMWEI PTC Thermistor Telecom Overcurrent Overload Protection Features

Compliant with ITU-T standards

  • basic-level lightning surges (10/700 µs)
  • basic-level power induction (600 V, 1 A, 0.2 s)
  • power contact criteria A/B (230 V, 15 min.)

Matching available with narrow resistance tolerance.
Tight resistance matching maintained after switching.
Negligible resistance drift after soldering or switching.

AMWEI PTC Thermistor Telecom Overcurrent Protection Specifications, EPCOS B59154U1135B140 Replacement

  • Resistance @25C  R25 : 50Ω,
  • Standard R25 tolerance +/-  20%, tight tolerance +/-  15% can be supplied upon request.
  • R25 resistance matching per packing unit can be supplied upon request.
  • Rated voltage (RMS) : 230 V
  • Maximum operating voltage Vmax: 650 V
  • Maximum permissible repetitive turn over current Imax: 3 A
  • Non-trip Current at +25C : 75 mA
  • Non-trip Current at +40C:  60 mA
  • PTC Thermistor Trip Current, Operating Current at +25℃ It : 150 mA
  • Tripping time at +25C:
    1A→ 0.5A: 0.35~0.65 seconds.
    0.5A→0.15A, 3 seconds
    0.35A→0.15, 6 seconds
  • Tripping time at max. current 3A: <0.2 seconds,
  • Operating ambient temperature range (V=0): -40~+125C
  • Operating ambient temperature range (V=230V) :  0~60C

AMWEI PTC Thermistor Telecom Overcurrent Protection Reliability Data

Test Item Standard Test conditions |ΔR25/R25|
Electrical endurance,
cycling
IEC 60738-1 Room temperature, 3A; 230V
Number of cycles: 10
<20%
Electrical endurance,
constant
IEC 60738-1 storage at Voltage: 230V
Ambient temperature: +60C
Test duration: 1000 h
<25%
Damp heat IEC 60738-1 Temperature of air: 40℃,
Relative humidity of air: 93%,
Duration: 56 days
Test according to IEC  60068-2-78
<10%
Lead wire tensile IEC60068-2-21 Test Ua: pull strength 10N, 10 seconds,
Test Ub: bending 90°, pull strength 5N,
successively twice.
Test Uc: revolving 180°,
successively twice.
<20%
Rapid change
of temperature
IEC 60738-1 T1 = Top,min (0 V), T2 = Top,max (0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, test Na
<10%
Climatic sequence IEC 60738-1 Dry heat: T = Top,max (0 V)
Test duration: 16 h
Damp heat first cycle
Cold: T = Top,min (0 V)
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
<10%

AMWEI PTC Thermistor for Telecom Overcurrent Protection Leaded Disk Coated ITU Performance

Test Item Condition Test Method Performance Requirement
Over Current Withstanding 220V/3A, 20 cycles Max. voltage of supply: 220VAC, Initial current: 3A. ON 60S, OFF 600S , Cycle:20 times, No damage, 4 hours after the conditioning then re-test Rn. Zero power resistance at 25℃ ΔR/Rn≤20%.
Lightning Surge Current Withstanding 10/1000μs, 30 cycles Duration: 30 times, Temperature: 25℃ Short circuit current wave:10/1000μs,  Minimum open voltage: 4 KV Short circuit current peak value: 25A Interval time: 3min No damage, 4 hours after the conditioning then re-test Rn. Zero power resistance at 25℃ ΔR/Rn≤20%.
Power Line Contact (Over Voltage Withstanding) 250V/3A, 15 minutes Duration: 1 cycle Ambient Temperature: 25 ± 2 ℃ Voltage: 250 Vrms Frequency: 50Hz Current: 3A, 15 minutes On No damage, 4 hours after the conditioning then re-test Rn. Zero power resistance at 25℃ ΔR/Rn≤20%.
Induction  Voltage Withstanding 650V/1.1A, 20 cycles Duration: 20 cycles Voltage: 650Vdc Temperature: 25℃ Current: 1.1A Cycle: 1 sec ON/60sec. OFF No damage, 4 hours after the conditioning then re-test Rn. Zero power resistance at 25℃ ΔR/Rn≤20%.
Fail Model 650V/10A, 30 minutes Voltage of power supply: 650VAC. Initial current: 10Arms. Energized time: 30min. High resistance or open circuit is allowable. Low resistance state or firing is not allowed

AMWEI PTC Thermistor for Telecom Overcurrent Protection Leaded Disk Coated Packaging

Loose bulk in plastic package.

AMWEI Ordering Code: AMZ23-50RM075