TDK EPCOS Code B59884C0120A070 Alternative, PTC Thermistor for Overcurrent Protection, Leaded Disk Coated 380V 600 Ohm 0.2A
AMWEI Ordering Code: AMZ11-05P601N420
Appearance and Dimension
- Silicon resin coated ceramic disk, green color
- Coated ceramic disk outer diameter D : 6.5mm max.
- Coated ceramic disk thickness T: 5.5mm max.
- 2 Tinned pin wire space F: 5.0± 1mm
- Pin wire diameter d: 0.6mm
- Pin wire length L: 25mm min.
- Ceramic body to kinked wire length H: 12mm max.
Features
- Application: Overcurrent protection, Overload, Short circuit protection.
- Best suited to meet the requirements for measuring instrumentation and meter circuit overload and short circuit protection, power supplies motor transformer protection.
- Error-free operations are assured by rush current.
- Circuit is protected until current is turned off.
- Restores the original low resistance value automatically once the overload is removed.
- Non-contact design leads to long life and no noise.
- Durable and strong against mechanical vibration and shock.
Electrical Specifications
- Resistance @25C R25 : 600Ω +/- 30%
- Rated voltage (RMS) : 380 V
- Maximum operating voltage Vmax: 420 V
- Maximum withstanding voltage Vwith: 650 V
- Maximum permissible repetitive turn over current Imax: 0.2A
- Non-trip Current at +25℃ : 21 mA
- Non-trip Current at +60℃: 16 mA
- PTC Thermistor Trip Current, Operating Current at +25℃ It : 39 mA
- Reference temperature (Switch temperature) Tref: 120 ℃
- Operating ambient temperature range (V=0): -40~+125C
- Operating ambient temperature range (V=Vmax) : 0~60C
Reliability Data
Test Item | Standard | Test conditions | |ΔR25/R25| |
---|---|---|---|
Electrical endurance, cycling |
IEC 60738-1 | Room temperature, 0.2A; 420V Number of cycles: 100 |
<25% |
Electrical endurance, constant |
IEC 60738-1 | storage at Voltage: 380V Ambient temperature: +60C Test duration: 1000 h |
<25% |
Damp heat | IEC 60738-1 | Temperature of air: 40℃, Relative humidity of air: 93%, Duration: 56 days Test according to IEC 60068-2-78 |
<10% |
Lead wire tensile | IEC60068-2-21 | Test Ua: pull strength 10N, 10 seconds, Test Ub: bending 90°, pull strength 5N, successively twice. Test Uc: revolving 180°, successively twice. |
<20% |
Rapid change of temperature |
IEC 60738-1 | T1 = Top,min (0 V), T2 = Top,max (0 V) Number of cycles: 5 Test duration: 30 min Test according to IEC 60068-2-14, test Na |
<10% |
Climatic sequence | IEC 60738-1 | Dry heat: T = Top,max (0 V) Test duration: 16 h Damp heat first cycle Cold: T = Top,min (0 V) Test duration: 2 h Damp heat 5 cycles Tests performed according to IEC 60068-2-30 |
<10% |
Packaging Information
Loose bulk, or Production tape package.
What is PTC Thermistor Current Protector Resettable Fuse
PTC Fuse Current Protection Application
How PTC Thermistor Current Protection Work? Operating Principle
PTC Thermistor Replacement Idea for a Resistor and Fuse solution
PTC 3 types over-current and overload protection
PTC thermistor circuit protection diagram examples
Transformer Protection 265V, 100C Data
(For PTC fuse installed inside transformer windings coil)
Transformer Protection 265V 120C Data
(For PTC fuse installed outside transformer windings coil)
PTC thermistor Current Protector Reliability Data
How to select PTC thermistor circuit protector for overcurrent and overload protection?
An example selecting AMWEI PTC thermistor for transformer overload protection.